What is Surge Protection?
The main job of a surge protection system is to protect electronic
devices from "surges." A power surge, or transient voltage, is a
considerable increase in voltage above the designated level during the
flow of electricity. Some of these surges can be caused by Electrostatic
Discharge, lighting strikes, etc…
In any electrical environment there are “electrical surge” types of
threats from Electrostatic Discharge (ESD) and lightning strikes, which
can cause loss of data or even in extreme cases permanent damage to your
electrical equipment.
ESD threats are can be created by a separation of charge that can
accumulate on equipment or an individual and then be discharged through
contact. Electrical Fast Transients (EFT), similar to that of an ESD,
disturbances can occur as a result of arcing (jumping electricity)
contacts in electro-mechanical switches and relays commonly found in heavy
density electrical environments.
Lastly, Lightning strikes can also create a large disturbance and delivery
of electricity to electrical equipment. These lightning strikes can cause
a differential in voltages to develop as a result of inductance in the
protective earth ground path to the equipment.
There are several types of hardware applications that are more likely to
promote electrical surges.
- Locations favorable to Electrical Storms
- Unshielded Cabling
- Outside Exposed Electrical Wiring
- Multiple Grounding Points
- Long Cable Runs
- Poorly Built wiring
What level of Surge Protection do Sena products support?
SENA Technologies is committed to developing the
highest quality products, with that in mind; surge protection is a main
concern when Sena Technologies develops their products. Sena Technologies
products are all FCC (Class A) and CE certified which meet their ESD
protection ratings of level 3.
The following table includes Sena Technologies Surge Protection ratings
for our Serial Device Server Line of Products:
|
Model |
ESD-protection
Serial Line Driver |
Built-in
Surge Protector |
ESD |
FCC/CE
|
Description |
Level 4
(15kV) |
Level 3
(8kV) |
|
LS100,
LS110 |
O |
X |
O |
O |
|
|
LS100W |
O |
O |
O |
O |
|
|
PS110,
PS410,
PS810,
PS110W,
PS210W |
O |
O |
O |
O |
|
|
RHIO10, RHIO232 |
O |
X |
O |
O |
Optically
Isolated |
|
UPSLink100 |
O |
O |
O |
O |
|
|
SS100,
STS400,
STS800,
STS1600 |
O |
O |
O |
O |
|
|
VTS400, VTS800,
VTS1600, VTS3200, VTS4800
|
O |
O |
O |
O |
|
|
VTS PM 8H, VTS PM 10V
|
O |
X |
O |
O |
|
For detailed information about this feature,